Purchased equipment: water cycle for power boiler
Location: WUXI China
Telephone: +86 13861509127
E-mail: [email protected]
Contact us for more details about our boilers, solutions and services.

water cycle for power boiler
Others

Molten salt heaters use molten potassium nitrate and sodium nitrite as heating media. Molten salt heater will heat the powder salt over the melting point until the viscosity of the molten salt allows circulating pump works, after the whole system is under circulating condition, then feed then into the thermal fluid heater for further circulating rising temperature to make it to be recycling used. Normal media working temperature is 400-550℃, top working temperature could reach 600℃.

Technical advantages

Digitized manufacture

  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of square coil tube adopts CNC three-dimensional tube bending machine, no forced shaping.
  • The manufacture of serpentuator adopts serpentuator automatic production line, once-forming.

Long life span

  • The optimized radiation heating surface and convective heating surface, the medium flow is more reasonable, without overheat of the carrier and reduce the life;
  • Convection section: optimize convection heating surface and adopt effective fix and structural support to make its working life longer.
  • Set up effective flue gas partition for convection heating surface and cast partition to make it works longer.

Less fuel consumption

  • Use superior refractory brick to build inside and superior perlite in the middle. Keep the furnace temperature under 50℃ to make the minimization of loss.
  • Furnace adopts double close line coil, which makes heating surface sufficient.

Add Comment

Enhanced water/steam cycle for advanced combined cycl

Enhanced Water/Steam Cycle for Advanced Combined Cycle Technology . Author: flexibility of the boiler and water chemistry. Siemens is the only company to have accumulated operational experience with raised steam Today’s combined cycle power plants (CCPP) have to fulfill challenging requirements in order

High-Pressure Steam Cycle and Boiler Water Treatme

•Steam cycle – Begins at the boiler where thermal energy in superheated steam is converted to mechanical energy in the propulsion turbine – Steam is then converted into condensate in the main condenser – Condensate is combined with distilled makeup water and is pumped as feedwater through heaters to a

Power Plant Steam Cycle Theory - EOL

on an open cycle where the exhaust steam was discharged to the atmosphere. This necessitated an adequate supply of fresh water. Impurities in the water accumulated in the bo iler during the steam generating process and some form of water treatment in the boiler or prior to the water entering the boiler was required.

VGB-Standard Feed Water, Boiler Water and Steam Qualit

Water, Boiler Water and Steam Quality for Power Plants / Industrial Plants. This new guideline replaces the former "VGB Guideline for Boiler Feed Water, Boiler Water and of Steam Generators with a Permissible Operating Pressure > 68 bar, October 1988 Edition".

A Large-Capacity Pressurized-Fluidized-Bed-Combustio

A Large-Capacity Pressurized-Fluidized-Bed-Combustion-Boiler Combined-Cycle Power Plant 108 All plant operations, from the start of the seawater system to the operation of the plant under a full load to the shut-down of the plant, were made sequential on a system-by-system basis to implement a fully-automated plant based on control computers. For

Application description AD/ANAINST/018-EN Hydrazin

Hydrazine, sodium and dissolved oxygen measurement The power of boiler chemistry Introduction Optimum positioning of analytical instruments at key points throughout the water and steam cycle and water treatment plant on modern power stations can provide operators with a valuable insight into improving plant efficiency and cost effectiveness.

Water Quality for Supercritical Plants - eecpowerindia.c

All boiler tube and turbine blade failures influenced by cycle water chemistry have the breakdown of the passive protective layer as part of the failure mechanism. If you protect your protective layer 24/7 seven days a week 365 days a year, you will not have boiler or turbine blade failures due to cycle chemistry.

Hrsg Power Plant Boiler Exhaust Find Be

Boiler Cleaning Methods & Techniques - Power . Keeping a power plant's boiler clean is an important part of increasing efficiency and avoiding forced outages. Power Engineering looks at different methods and practices for cleaning boilers. Keeping a power plant's boiler clean is . Learn More

Water Treatment, Cycle Chemistry, Boiler Operation an

This paper deals with steam generators of industrial plants (shell boiler & water-tube boiler) as well as with waste heat recovery boiler (HRSG) downstream of gas turbines of combined cycle power plants (CCPP) and waste heat boiler (WHB) in refineries and petrochemical plants.

Rankine cycle - Wikiped

The actual vapor power cycle differs from the ideal Rankine cycle because of irreversibilities in the inherent components caused by fluid friction and heat loss to the surroundings; fluid friction causes pressure drops in the boiler, the condenser, and the piping between the components, and as a result the steam leaves the boiler at a lower

Combined-Cycle Water/Steam Monitoring - Power Engineeri

Brad Buecker is a process specialist with Kiewit Power Engineers in Lenexa, Kan., and a contributing editor for Power Engineering. "Boiler water pH is one of the few samples where an immediate

text