Purchased equipment: incinerator waste heat boiler for sru
Location: WUXI China
Telephone: +86 13861509127
E-mail: [email protected]
Contact us for more details about our boilers, solutions and services.

incinerator waste heat boiler for sru
Others

Molten salt heaters use molten potassium nitrate and sodium nitrite as heating media. Molten salt heater will heat the powder salt over the melting point until the viscosity of the molten salt allows circulating pump works, after the whole system is under circulating condition, then feed then into the thermal fluid heater for further circulating rising temperature to make it to be recycling used. Normal media working temperature is 400-550℃, top working temperature could reach 600℃.

Technical advantages

Digitized manufacture

  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of square coil tube adopts CNC three-dimensional tube bending machine, no forced shaping.
  • The manufacture of serpentuator adopts serpentuator automatic production line, once-forming.

Long life span

  • The optimized radiation heating surface and convective heating surface, the medium flow is more reasonable, without overheat of the carrier and reduce the life;
  • Convection section: optimize convection heating surface and adopt effective fix and structural support to make its working life longer.
  • Set up effective flue gas partition for convection heating surface and cast partition to make it works longer.

Less fuel consumption

  • Use superior refractory brick to build inside and superior perlite in the middle. Keep the furnace temperature under 50℃ to make the minimization of loss.
  • Furnace adopts double close line coil, which makes heating surface sufficient.

Add Comment

TAIL GAS UNIT FOR A SULFUR RECOVERY UNIT - She

incinerator waste heat boiler, which is then recycled back to the SRU reaction furnace. The additional SO 2 reduces both the reaction furnace temperature as well as the air volume allowing for a 70 TPD increase in SRU capacity. PROJECT EXECUTION: The CANSOLV unit was installed in a crowded area of the refinery containing the SRU without incident.

Welcome to Thermal Syste

Thermal Systems started a humble beginning in 1985 and gradually grown to be a major player in concept to Commissioning of Waste Heat Recovery Boiler for varied applications, backed with a Core team of highly skilled professionals of various disciplines.

Sulfur Tail Gas Thermal Oxidizer Waste Characterizatio

requirements and whether or not waste heat recovery equipment is located downstream. It is generally not acceptable to supply a natural draft burner for a system with heat recovery. The pressure drop of the flue gas through a superheater or waste heat recovery boiler is usually too great for natural draft alone to overcome. The

SULPHUR RECOVERY UNIT - UniverSUL Consulti

SULPHUR RECOVERY UNIT START-UP CONSIDERATIONS SHRIKANT KOLI BLACK & VEATCH, MUMBAI. 2 Control Loops in SRU Incinerator Temperature Control/Oxygen Control ps. 10 Refractory Dry-Out Purpose - Pressure in Waste Heat Boiler steam drum is increased in

Optimal Decision Support System Using Multilayer Neura

of the incinerator used in SRU is shown in figure 1. The hot flue gas from thermal oxidizer mixing chamber is passed through incinerator waste heat boiler to recover heat from the gas. Steam is generated. The flue gas from incinerator waste heat boiler at 325oC is discharged to the incinerator stack.

ZEECO PRODUCTS & INDUSTRIES | Incinerators & Therma

Sulfur Recovery Unit (SRU) Reaction Furnace. The reaction furnace is the heart of the Sulfur Recovery Unit (SRU), initiating the conversion of H2S and other sulfur-bearing compounds to elemental sulfur.

SRU Brochure ZEECO | Incineration | N

This waste heat boiler generates waste heat steam while cooling the reaction furnace effluent. In the absence of licensor input. many Zeeco systems incorporate waste heat recovery equipment to further reduce operating costs by generating steam and/or heating oil that is used for other plant operations.

Sulfur Tail Gas Thermal Oxidizer Waste Characterizatio

requirements and whether or not waste heat recovery equipment is located downstream. It is generally not acceptable to supply a natural draft burner for a system with heat recovery. The pressure drop of the flue gas through a superheater or waste heat recovery boiler is usually too great for natural draft alone to overcome. The

IMPROVING SRU REACTION FURNACE RELIABILITY: BOILER TUB

• Supplied tubesheet ferrules for over 25,000 SRU’s • Worked with Engineering and Licensing companies, consultants, boiler manufacturers, refractory installers and End Users to establish optimal and reliable operation of tubesheet refractory installations in sulphur recovery units.

Top Five Fundamental Integrity Issues for SRU Waste Hea

SRU Overpressure in a Waste Heat Boiler Failure – Justin Lamar, Black & Veatch Justin will discuss the aspects of WHE tube failure, API 521 evaluations, and SRU pressure buildup. He will review a case history of a reported tube failure and associated SRU pressure buildup.

Refining & Petrochemicals | Calder

SRU - Main Burner, Main Combustion Chamber and Waste Heat Boiler. Ethylene Cracker (Naphtha Cracker) Primary Reformer. Secondary Reformer. SRU - Line Burner and Line Mixing Chamber. SRU - Incinerator Burner, Incinerator Chamber, and Waste Heat Boiler. SRU - Condensers. SRU - Reactor. Contact.

text