Purchased equipment: waagner biro steam boiler
Location: WUXI China
Telephone: +86 13861509127
E-mail: [email protected]
Contact us for more details about our boilers, solutions and services.

waagner biro steam boiler
Others

Molten salt heaters use molten potassium nitrate and sodium nitrite as heating media. Molten salt heater will heat the powder salt over the melting point until the viscosity of the molten salt allows circulating pump works, after the whole system is under circulating condition, then feed then into the thermal fluid heater for further circulating rising temperature to make it to be recycling used. Normal media working temperature is 400-550℃, top working temperature could reach 600℃.

Technical advantages

Digitized manufacture

  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of square coil tube adopts CNC three-dimensional tube bending machine, no forced shaping.
  • The manufacture of serpentuator adopts serpentuator automatic production line, once-forming.

Long life span

  • The optimized radiation heating surface and convective heating surface, the medium flow is more reasonable, without overheat of the carrier and reduce the life;
  • Convection section: optimize convection heating surface and adopt effective fix and structural support to make its working life longer.
  • Set up effective flue gas partition for convection heating surface and cast partition to make it works longer.

Less fuel consumption

  • Use superior refractory brick to build inside and superior perlite in the middle. Keep the furnace temperature under 50℃ to make the minimization of loss.
  • Furnace adopts double close line coil, which makes heating surface sufficient.

Add Comment

waagner biro steam boiler – Industrial Boiler Catalog

VKW R/H Boilers main steam at 126 bar 510 C 510 C High Pressure boilers main steam at 96 bar 510 C manufactured by Waagner Biro Austria. Waagner Biro Gulf LLC | Tel – +971 4 2611528, Dubai | Online Get complete information of Waagner Biro Gulf LLCwith tel- +971 4 2611528, , Dubai at Yellowpages.ae.

Rehabilitation of the Ataka power station, boilers 1 +

At the beginning of the 1980s, Waagner- Biro erected two oil- and gas-fired steam boilers (boilers 1 -H 2) at the Ataka power station in Suez/Egypt. Each boiler had an output of 150 MW. In the

Gas and Oil Fired Power Plant (120 MW and 164 MW) | Salv

Boiler incl. water / steam system and flue gas path systems Steam turbine and condensing plant incl. auxiliaries Cooling plant incl. cooling water inlet equipment

COAL FIRED POWER GENERATION PROJECT (330M

Manufacturer Waagner-Biro (Austria Energy) Type Once- trough boiler, 100m high Capacity 980 t/h Design pressure 203 bar Live steam 184 bar / 535 oC Reheat cycle 535 oC Fuel Coal powder Coal mills 6 EVT coal mills Ignition / start- up firing 280 t/h HFO Exhaust gas temperature 150 oC Flue Gas Cleaning (FGD) Manufacturer Waagner-Biro Process

Benson Boilers | Boiler | Power Station - Scri

The two main configurations for the BENSON boiler to date are the single-pass and two-pass design Cumulative steam capacity of ordered BENSON boilers 200.The BENSON boiler design is adapted to the fuel and local conditions.000 0 1946 1956 1966 1976 1986 1996 1998 Bituminous coal.07 walls • Low erosion of heating independent of furnace

Waagner-Biro | Revol

Waagner-Biro Waagner-Biro is a Vienna, Austria-based corporation which owns companies in steel and mechanical engineering. It has about 1000 employees in 14 locations in Europe, Asia, and the Middle East.

NOX Reduction Technology of IHI Denitrification (SC

(SCR)plant using a honeycomb catalyst for dirty exhaust gas from an oil fired utility boiler was delivered at the end of the (Waagner-Biro Energy ; Environment GesmbH

Steam generators - Waagner-Biro Aktiengesellscha

A steam generator which is particularly adapted to be used in nuclear power plants. A casing is provided with an inlet and outlet to receive and discharge a primary heating fluid from which heat is to be extracted.

BENSON Boilersfor Maximum Cost-Effectiveness in Power Plan

(SGP/Waagner-Biró) FLS miljø controlled in the BENSON boiler such that the desired steam temperature is always established at the main steam outlet.This is made possible by the variable evaporation endpoint.The eva-poration and superheating surfa-ces automatically adjust to ope-

Pipeline Bridges Mellach - References - Bridge Constructio

Siemens Energy, as a general contractor, has been building a gas and steam power plant in Mellach. The company INTEGRAL commissioned Waagner-Biro

EP0359735A1 - Waste heat boiler - Google Paten

A waste heat boiler having a feed water container, which exercises the function of a steam collecting drum, preferably a low-pressure drum (12).

text