bfw poduction fir high pressure boiler
Others

Molten salt heaters use molten potassium nitrate and sodium nitrite as heating media. Molten salt heater will heat the powder salt over the melting point until the viscosity of the molten salt allows circulating pump works, after the whole system is under circulating condition, then feed then into the thermal fluid heater for further circulating rising temperature to make it to be recycling used. Normal media working temperature is 400-550℃, top working temperature could reach 600℃.

Technical advantages

Digitized manufacture

  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of square coil tube adopts CNC three-dimensional tube bending machine, no forced shaping.
  • The manufacture of serpentuator adopts serpentuator automatic production line, once-forming.

Long life span

  • The optimized radiation heating surface and convective heating surface, the medium flow is more reasonable, without overheat of the carrier and reduce the life;
  • Convection section: optimize convection heating surface and adopt effective fix and structural support to make its working life longer.
  • Set up effective flue gas partition for convection heating surface and cast partition to make it works longer.

Less fuel consumption

  • Use superior refractory brick to build inside and superior perlite in the middle. Keep the furnace temperature under 50℃ to make the minimization of loss.
  • Furnace adopts double close line coil, which makes heating surface sufficient.

Add Comment

Water Treatment, Cycle Chemistry, Boiler Operation an

This high quality BFW is essentially for spray water de- super-heating and application of “All Volatile Treatment” AVT. Boiler water (BW) is the water circulating within the boiler.

OPERATING MANUALS - Utility Boilers Rev

pumped by the BFW pumps to the high and medium pressure BFW headers. Boiler Feed Water Pump, is driven by a steam turbine. The steam turbine uses high pressure steam(1500 psig) and exhausts low pressure steam(50 psig) to the low pressure steam header. Each BFW pump has an Automatic Recirculation Control Valve. This valve is designed

Boiler water Limit:- - Altr

The following are specified limit for high pressure boiler from different organization:- ASME Guidelines for Water Quality in Modern Industrial Water Tube Boilers for Reliable Continuous Operation:-Boiler Feed Water Boiler Water Drum Pressure (psi) Iron (ppm Fe) Copper (ppm Cu) Total Hardness (ppm CaCO3) Silica (ppm SiO 2) Total Alkalinity**

BFW Heaters - Sulphuric Ac

The boiler feed water flows through the tubeside of the BFW heaters. If possible, the system should be designed so the BFW pressure is higher than the acid pressure. This will ensure that if a leak occurs, leakage will be from the water side into the acid side, thus reducing the chance of contaimination of the BFW.

BFW Pumps - Sulphuric Ac

The steam turbine will generally be a single-stage turbine with the exhaust steam discharged to a low pressure header. Minimum Recycles. At low or no flow conditions, a multistage high-head BFW pump can easily generate excessive pressure and heat which can lead to pump failure.

energi efisiensi tinggi pemanas listrik ketel uap bersih boile

bfw poduction fir high pressure boiler steam king boiler Henan Sitong Boiler Co., Ltd Meet the professional industrial boiler manufacturer Sitong Boiler is the professor of of

Steam Digest 2001 - NREL - PDF Free Downlo

Steam leaks can result from failures associated with improper piping design, corrosion problems, and valves. In high-pressure industrial steam systems, the energy costs associated with steam leaks can be substantial.

Boiler Feed Water Treatment for Industrial Boilers an

By Michele Monroe. In the steam boiler industry, high purity feed water is required to ensure proper operation of steam generation systems. High purity feed water reduces the use of boiler chemicals due to less frequent blowdown requirements (reducing blowdown frequency by as much as a factor of 10).

Using of congruent phosphate as equilibrium phosphat

Coordinated and congruent phosphates boiler water treatment has been used for more than forty years. They are very effective scale inhibitors for low and high pressure boilers.

BFW pumps in processing plants - Processing Magazi

BFW pumps are a special class of pumps: They are relatively large, high-power, high-pressure pumps that move BFW to boilers. They are the backbone of any generation system, and they determine the pressure of the generated steam.