Molten salt heaters use molten potassium nitrate and sodium nitrite as heating media. Molten salt heater will heat the powder salt over the melting point until the viscosity of the molten salt allows circulating pump works, after the whole system is under circulating condition, then feed then into the thermal fluid heater for further circulating rising temperature to make it to be recycling used. Normal media working temperature is 400-550℃, top working temperature could reach 600℃.

Technical advantages

Digitized manufacture

  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of square coil tube adopts CNC three-dimensional tube bending machine, no forced shaping.
  • The manufacture of serpentuator adopts serpentuator automatic production line, once-forming.

Long life span

  • The optimized radiation heating surface and convective heating surface, the medium flow is more reasonable, without overheat of the carrier and reduce the life;
  • Convection section: optimize convection heating surface and adopt effective fix and structural support to make its working life longer.
  • Set up effective flue gas partition for convection heating surface and cast partition to make it works longer.

Less fuel consumption

  • Use superior refractory brick to build inside and superior perlite in the middle. Keep the furnace temperature under 50℃ to make the minimization of loss.
  • Furnace adopts double close line coil, which makes heating surface sufficient.

Add Comment

Factory owners must ensure the boiler is - labour.gov.

2. Features of Fire-Tube Boilers 7 3. Flashing Up Procedure 9 4. Testing of Gauge Glass 11 5. Low-water Level Cut-Off Switch 16 6. Steam Pressure Testing of Safety Valve 17 7. Testing of Steam Pressure Switch 18 8. Testing of Flame Detector 19 9. Fire-Tube Boiler Emergencies 19 10. Handling of Boiler Fires 20 11.

Oil Fired Boiler Startup Procedure - drhardiedebeer.co.

shutdown procedure of firetube boiler – Star Boiler. Thermidaire boiler shutdown procedure Unless suitable procedures are observed during the entire shutdown process, For a watertube boiler, the washing procedure should start in the steam drum, Boiler Shutdown, – Banks . Learn More

Fire Tube Boiler Shutdown Procedure Best Pri

Fire Tube Boiler Shutdown Procedure Best Price. Water Tube Boiler | Operation and Types of Water Tube Boiler. A water tube boiler is such kind of boiler where the water is heated inside tubes and the hot gasses surround them. This is the basic definition of water tube boiler. Actually this boiler is just opposite of fire tube boiler where hot

Boiler Inspections - Veolia Wat

required to help remove suspended solids in the boiler prior to shutdown. Follow the boiler manufacture s cool down procedure and be sure to rinse out the boiler as soon as the boiler is cool to avoid dried and baked on sludge deposits later on. If the cooled boiler is to be left filled with water for an extended period of

BOILER COLD STARTUP PROCEDURE | Charcoal | Furna

BOILER COLD STARTUP PROCEDURE 1. 2. 3. Check and ensure the furnace is cleaned from any foreign materials. Boiler Fundamental & Water Circulation System Mdified. Uploaded by. Sam. Boiler Book. Uploaded by. arganesan. 135MW CFBC Operation Manual 1(20080306) Cfbc Boiler Startup_load Operation_shutdown. Uploaded by. Ashvani Shukla. Design

Thermidaire boiler shutdown procedu

Boiler Shutdown Procedure . Boiler Shutdown Procedure. When a boiler is taken out of service, take special precautions to prevent mechanical damage. boiler water contains solids suspended by water circulation and the action of dispersant treatment chemicals. Unless suitable procedures are observed during the entire shutdown process

Appendix 16 Emergency Shutdown Procedure Potentia

measures to be taken to rectify over pressure in the boiler will be the same as for the furnaces. Another abnormal situation that could occur in the boiler would be a boiler tube leak, which would result in boiler feed water leaking into the flue gases.

Boiler Operation Training - from Start-up to Lay-

3-4 % by volume (for fire tube boiler). 0.5-1.5 % by volume (for water tube boiler with high efficiency burners). 2. Carbon Dioxide: 12 to 14 % by volume, the higher the readings, the better the combustion efficiency. It must be remembered that the CO2 reading changes with the fuel type/ quality and the level of excess air supplied to the

12 Ways To Avoid Boiler Tube Corrosion - BOILERSMI

regular feed water. After every filling, a steam boiler should be heated to bring the water to a good boil and the steam so produced should be vented off to carry the released gases out of the boiler. Before this boil out, water treating chemicals should be added so as to get good mixing.

Boiler Operation Made Easy : Procedure for Starting an

Check and open the feed water valves to the boiler and fill the water inside the boiler drum to just above the low water level. This is done because it is not possible to start the boiler below the low water level due to safety feature which prevent boiler from starting.

Section 2 START-UP AND OPERATION STEAM BOILE

lowering the boiler water level (by opening the boiler blowdown valve for probe controls, and by opening the control blowdown valve for float type controls). The boiler should cycle off when the water level drops below the control point of the low water cut-off. When the water level is restored, the boiler should cycle back on.